+8618060982349

وحدة الفصل الجلفاني GSI127-021 244-127-000-021 A2-B02

GSI127-021 244-127-000-021 A2-B02 وحدة تغذية طاقة لأجهزة الاستشعار و/أو مُكيّفات الإشارة ذات خرج تيار أو خرج جهد

  • رقم الصنف.:

    GSI127-021
  • دفع:

    T/T
  • سعر السوق:

    $1850
  • أصل المنتج:

    Switzerland
  • اللون:

    Depends on material
  • ميناء الشحن:

    Xiamen
  • المهلة:

    5-7 days
  • الأسهم السلع:

    30
  • وزن المنتج:

    0.14 kg

التصنيع
Vibration
Model
GSI127
PN No. 244-127-000-021 A2-B02
Catalog
NIL
Description
Galvanic Separation Unit
Origin Switzerland
HS CODE 85389091
Dimension 12*12*2.5 (CM)
Weight 0.14 kg

Description:

The GSI127 is a galvanic separation unit from Meggitt’s vibro-meter product line. It is designed for operation with the signal conditioners, charge amplifiers and electronics (attached or integrated) used by various vibro-meter measurement chains and/or sensors.
Compatible devices include the IPC707 signal conditioners (charge amplifiers) used by CAxxx piezoelectric accelerometers and CPxxx dynamic pressure sensors (and older IPC704 signal  conditioners too), the IQS9xx signal conditioners used by TQ9xx proximity sensors (and older IQS4xx signal conditioners too), the attached or integrated electronics used by CExxx piezoelectric accelerometers, and the integrated electronics used by the VE210 velocity sensor. The GSI127 is also compatible with industry standard IEPE (integrated electronics piezo electric) vibration sensors, that is, the integrated electronics used by constant-current voltage output sensors such as the CE620 and PV660 (and older CE680, CE110I and PV102. sensors too).
The GSI127 galvanic separation unit is a versatile unit that can is used for the transmission of high frequency AC signals over long distances in measurement chains using current-signal transmission or as a safety barrier unit in measurement chains using voltage-signal transmission. More generally, it may be used to supply any electronic system (sensor side) having a consumption of up to 22 mA.
The GSI127 also rejects a large amount of the frame voltage that can introduce noise into a measurement chain. (Frame voltage is the ground noise and AC noise pickup that can occur between the sensor case (sensor ground) and the monitoring system (electronic ground) ). In addition, its redesigned internal power supply results in a floating output signal, eliminating the need for an additional external power supply such as an APF19x.

The GSI127 is certified to be installed in an Ex Zone 2 (nA) when supplying measurement chains installed in Ex environments up to Zone 0 ( [ ia ] ). The unit also eliminates the need for additional external Zener barriers in intrinsic safety (Ex i) applications.

The GSI127 housing features removable screw terminal connectors that can unplugged from the main body of the housing to simplify installation and mounting. It also features a DIN-rail mounting adaptor that allows it to be mounted directly on a DIN rail.
GSI127 244-127-000-017A1-B02

Order number:

GSI127 244-127-000-017-A2-B5
GSI127 244-127-000-017-A1-B02
GSI127 244-127-000-017-A1-B02

GSI127 244-127-000-017-A2-B01

GSI127 244-127-000-017-A2-B03

GSI127 244-127-000-017-A2-B02


GSI127 244-127-000-021-A2-B5
GSI127 244-127-000- 021 -A1-B02
GSI127 244-127-000- 021 -A1-B02

GSI127 244-127-000- 021 -A2-B01

GSI127 244-127-000- 021 -A2-B03

GSI127 244-127-000- 021 -A2-B02


Ordering Information: GSI127 Galvanic Separation Unit
To order this product, please specify the Type, Designation, and the specific Part Number (PNR) derived from the configuration options below.
Base Ordering Number (PNR): 244-127-000-021

1. Environment Options (A)
Select the version based on the installation environment:
Standard: For use in non-hazardous areas; features a completely gray housing.
Explosive (Ex): Certified for use in potentially explosive atmospheres (Hazardous Areas). The housing is gray with a blue screw-terminal connector for sensor-side signals.

2. Transfer Function Options (B)
Choose the option code that matches your specific measurement chain or sensor type:

Option Code (B) Sensitivity Zero (Offset) Typical Application / Compatibility
01 Standard

5mA 7V

vibro-meter® CExxx sensors with current output

02 1V/mA

12mA 7V/

13mA 7V

IPCxxx signal conditioners or VE210 sensors with current output

03

3.2V/m A

15mA 0V

IQS90x (or IQS4xx) conditioners with current output

04 1V/V ---

IPCxxx signal conditioners with voltage output

05- -1V/V ---

IQS90x, IQS4xx, or VE210 with voltage output

11 0.5V/mA ---

IQS91x or industry-standard 4 to 20 mA loop-powered sensors

21 1V/V ---

Industry-standard IEPE sensors (e.g., CE620, CE630, PV660)

1. Only CExxx piezoelectric accelerometers with a current output signal require a GSI127. For example, the CE134, CE281 and CE31x.

2. An IPCxxx signal conditioner or a VE210 velocity sensor with a current output signal is typically used for signal transmission over longer distances.Note: For an IPC707 without diagnostics, the nominal current output signal (DC) is 12 mA (→ 7 V). For an IPC707 with diagnostics, the nominal current output signal (DC) is 13 mA (→ 8 V). Refer to the IPC707 signal conditioner data sheet for further information.
3. An IQSxxx signal conditioner with a current output signal is typically used for signal transmission over longer distances.
4. An IPCxxx signal conditioner with a voltage output signal is typically used for signal transmission over shorter distances.Note: For an IPC707 without diagnostics, the nominal voltage output signal (DC) is 7 V. For an IPC707 with diagnostics, the nominal voltage output signal (DC) is 8 V. Refer to the IPC707 signal conditioner data sheet for further information.
5. An IQSxxx signal conditioner or a VE210 velocity sensor with a voltage output signal is typically used for signal transmission over shorter distances.
6. For use with industry standard IEPE (integrated electronics piezo electric) vibration sensors, that is, constant-current voltage-output sensors such as the CE620 and PV660 (and older CE680, CE110I and PV102 sensors).

Datasheet Link:

GSI127-021 244-127-000-021 A2-B02 Galvanic Separation Unit Datasheet

GSI127 244-127-000-017 A2-B05

一年保修插画-一年保修手绘-一年保修卡通图-摄图新视界

ترك رسالة
إذا كانت أنت مهتم بمنتجاتنا وتريد معرفة المزيد من التفاصيل، يرجى ترك رسالة هنا، وسوف نقوم بالرد عليك حالما نحن CAN.
منتجات ذات صله
TQ902
TQ902111-902-000-011 مستشعرات القرب Meggitt Vibro-Meter
بائع ساخن ، مرحبًا بكم في الاستفسار
عرض المزيد
EA902
كابل تمديد EA902913-902-000-011 Meggitt Vibro-Meter
بائع ساخن ، مرحبًا بكم في الاستفسار
عرض المزيد
RPS6U
RPS6U 200-582-915-032 PSB915 اللوحة الخلفية لإمدادات الطاقة للرف
RPS6U 200-582-915-032 PSB915 اللوحة الخلفية لإمدادات الطاقة للرف
عرض المزيد
CE311
CE311 اهتزاز 444-311-000-021 مقياس تسارع كهرضغطي
CE311 اهتزاز 444-311-000-021 مقياس تسارع كهرضغطي
عرض المزيد
VMD110100CTVO
VMD110100CTVO مقياس اهتزازي

VMD110100CTVO مقياس اهتزازي

عرض المزيد
IP172
مجموعة تركيب حماية التوصيلات IP172 500-172-000-011
مجموعة تركيب حماية التوصيلات IP172 500-172-000-011
عرض المزيد
EA402
EA402 912-402-000-013 A1-E045-F1-G038 كابل التمديد
علامة تجارية جديدة بسعر منخفض، نرحب بعرض أسعارها
عرض المزيد

انقر هنا لترك رسالة

ترك رسالة
إذا كانت أنت مهتم بمنتجاتنا وتريد معرفة المزيد من التفاصيل، يرجى ترك رسالة هنا، وسوف نقوم بالرد عليك حالما نحن CAN.

منزل، بيت

منتجات

حول

اتصل