التصنيع
Vibration
Model
MPC4
PN No. 200-510-070-113
Catalog
NIL
Description
Machinery Protection Card
Origin Switzerland
HS CODE 85389091
Dimension 12*11*8 (CM)
Weight 0.5 kg

Description:

The MPC4 machinery protection card is the central element in the VM600 series machinery protection system (MPS), from Meggitt Sensing Systems’ Vibro-Meter® product line. This very versatile card is capable of measuring and monitoring up to four dynamic signal inputs and up to two speed inputs simultaneously.


The dynamic signal inputs are fully programmable and can accept signals representing acceleration, velocity and displacement (proximity), among others. On-board multi-channel processing allows measurement of various physical parameters, including relative and absolute vibration, Smax, eccentricity, thrust position, absolute and differential housing expansion, displacement and dynamic pressure.


Digital processing includes digital filtering, integration or differentiation (if required), rectification (RMS, mean value, true peak or true peak-to-peak), order tracking (amplitude and phase) and measurement of the transducer-target gap.


The speed (tachometer) inputs accept signals from a variety of speed sensors, including systems based on proximity probes, magnetic pulse pick-up sensors or providing TTL signals. Fractional tacho ratios are also supported.


The calibration may be expressed in metric or imperial units. Alert and Danger set points are fully programmable, as are alarm time delay, hysteresis and latching. The Alert and Danger levels can be adapted as a function of the speed or any external information.


A digital output is available internally (on the corresponding IOC4T card) for each alarm level.These alarm signals may be routed on a bus within the VM600 rack to drive relays on optional relay cards (such as the IRC4 and RLC16).


The processed dynamic (vibration) signals and speed signals are available at the rear of the rack (on the front panel of the IOC4T) as analog output signals. Voltage-based (0 to 10 V) and current-based (4 to 20 mA) signals are provided.


The MPC4 performs a self-test and diagnostic routine on power-up. In addition, the card’s built-in “OK System” continuously monitors the level of signals provided by the sensors and indicates any problem due to a broken transmission line, faulty transducer or conditioner.


An LED indicator on the MPC4 front panel indicates whether a processing or hardware error has occurred. Six additional LEDs (one per input channel) indicate whether the OK System has detected a fault and whether an alarm has occurred on the channel

1. Input & Measurement Capability

Feature Specification
Number of Inputs

4 Dynamic signal inputs + 2 Tachometer (speed) inputs

Input Signal Types

Acceleration, Velocity, Displacement (Proximity), and Dynamic Pressure

Tachometer Range

0.016 Hz to 50 kHz (supports fractional tacho ratios)

DC Range

0 to +20 V or 0 to -20 V

Frequency Band

0.1 Hz to 10 kHz (up to 60 kHz for buffered outputs)

2. Monitoring & Alarm Logic
Feature Specification
Alarm Set Points

Programmable Alert, Danger, and OK set points

Monitoring Modes

Relative/Absolute vibration, Smax , eccentricity, thrust position

Alarm Scanning

100 ms maximum interval

Logic Combinations

AND, OR, and majority voting logic (8 basic + 4 advanced functions)

Adaptive Levels

Levels can be adapted as a function of speed or external info

3. System & Safety Standards

Feature

Specification
API 670 Compliant

Strict segregation between MPS and CMS functions

Safety Certification

Certified to IEC 61508 (SIL) and ISO 13849 standards

Live Insertion

Supports live insertion and removal of cards (Hot-swappable)

Self-Test System

Continuous "OK System" monitoring for sensor/line faults

4. Physical & Environmental
Feature Specification
Operating Temp

-25 to +65 °C (-13 to +149 °F)

Humidity

0 to 90% non-condensing

Dimensions

6U Height (262 mm) x 20 mm Width x 187 mm Depth

Power Consumption

12.5 W (+1 W per sensor used)

Ordering Number:

MPC4 200-510-063-034
MPC4 200-510-070-113
MPC4 200-510-071-113
MPC4 200-510-076-114
MPC4 200-510-150-011
MPC4 200-510-150-031

MPC4 200-510-078-115

MPC4 200-510-074-114

MPC4 200-510-SSS-1Hh


Datasheet Link:

MPC4 Vibration 200-510-077-313 Machinery Protection Card Card Datasheet

一年保修插画-一年保修手绘-一年保修卡通图-摄图新视界
ترك رسالة
إذا كانت أنت مهتم بمنتجاتنا وتريد معرفة المزيد من التفاصيل، يرجى ترك رسالة هنا، وسوف نقوم بالرد عليك حالما نحن CAN.
منتجات ذات صله
TQ902
TQ902111-902-000-011 مستشعرات القرب Meggitt Vibro-Meter
بائع ساخن ، مرحبًا بكم في الاستفسار
عرض المزيد
EA902
كابل تمديد EA902913-902-000-011 Meggitt Vibro-Meter
بائع ساخن ، مرحبًا بكم في الاستفسار
عرض المزيد
RPS6U
RPS6U 200-582-915-032 PSB915 اللوحة الخلفية لإمدادات الطاقة للرف
RPS6U 200-582-915-032 PSB915 اللوحة الخلفية لإمدادات الطاقة للرف
عرض المزيد
CE311
CE311 اهتزاز 444-311-000-021 مقياس تسارع كهرضغطي
CE311 اهتزاز 444-311-000-021 مقياس تسارع كهرضغطي
عرض المزيد
VMD110100CTVO
VMD110100CTVO مقياس اهتزازي

VMD110100CTVO مقياس اهتزازي

عرض المزيد
IP172
مجموعة تركيب حماية التوصيلات IP172 500-172-000-011
مجموعة تركيب حماية التوصيلات IP172 500-172-000-011
عرض المزيد
EA402
EA402 912-402-000-013 A1-E045-F1-G038 كابل التمديد
علامة تجارية جديدة بسعر منخفض، نرحب بعرض أسعارها
عرض المزيد

انقر هنا لترك رسالة

ترك رسالة
إذا كانت أنت مهتم بمنتجاتنا وتريد معرفة المزيد من التفاصيل، يرجى ترك رسالة هنا، وسوف نقوم بالرد عليك حالما نحن CAN.

منزل، بيت

منتجات

حول

اتصل